Skip to content

Conversation

@JulianKunkel
Copy link
Contributor

Removing extended mode from IO500 and any other phase as this is following "rules".

@JulianKunkel JulianKunkel requested a review from a team as a code owner August 6, 2025 17:19
Copy link
Contributor

@gflofst gflofst left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Random 4kB I thought we had agreed through the process to include it as a test phase. These changes seem to remove it too. If we haven't done process properly, let's correct that so we can continue that test since we all agreed to it already.

@adilger
Copy link
Contributor

adilger commented Aug 7, 2025

Jay, there are two different random phases. The one in question here is not the same as the ior-rnd4k-easy-read phase that was added in the last round of discussions, but an older version of the same.

@gflofst gflofst self-requested a review August 7, 2025 19:15
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

5 participants