Skip to content

Conversation

@esmeknabe
Copy link
Contributor

…wer supply wiring

This will make the experiment more accurate, since before this change the SiPM array was only producing about 0.84 W of power (0.0525 W per SiPM). Now, the array is producing closer to 1.036 W which better models the expected dark current production

@esmeknabe
Copy link
Contributor Author

I also just added some new functionalities for the thermistor temperature versus time plots and updated some of the readme's